Please note that the copy function is not enabled for this field.
If you wish to
modify
existing outcomes, please copy and paste the current outcome text into the Update field.
LOGIN
CREATE ACCOUNT
LOGIN
CREATE ACCOUNT
MY TRIALS
REGISTER TRIAL
FAQs
HINTS AND TIPS
DEFINITIONS
Trial Review
The ANZCTR website will be unavailable from 1pm until 3pm (AEDT) on Wednesday the 30th of October for website maintenance. Please be sure to log out of the system in order to avoid any loss of data.
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been endorsed by the ANZCTR. Before participating in a study, talk to your health care provider and refer to this
information for consumers
Download to PDF
Trial registered on ANZCTR
Registration number
ACTRN12610000853044
Ethics application status
Approved
Date submitted
24/09/2010
Date registered
13/10/2010
Date last updated
24/02/2014
Type of registration
Prospectively registered
Titles & IDs
Public title
A prospective Radiostereometric Analysis (RSA) study of the cemented Total Hip System (E2 stem/ P2 cup) in patients with degenerative hip disease
Query!
Scientific title
A prospective Radiostereometric Analysis (RSA) study to predict long -term safety and effectiveness of the cemented Total Hip System (E2 stem/ P2 cup) in patients with degenerative hip disease
Query!
Secondary ID [1]
252752
0
Nil
Query!
Universal Trial Number (UTN)
Query!
Trial acronym
Query!
Linked study record
Query!
Health condition
Health condition(s) or problem(s) studied:
Degenerative hip disease
258253
0
Query!
Condition category
Condition code
Musculoskeletal
258442
258442
0
0
Query!
Osteoarthritis
Query!
Intervention/exposure
Study type
Interventional
Query!
Description of intervention(s) / exposure
The E2 stem is a cemented femoral device made of chrome-cobalt alloy. The stem has a double tapered geometry to aid the taper- slip theory of cement fixation.
The P2-cup is an all-polyethylene acetabular component intended for cemented fixation. The polyethylene cup is manufactured from highly cross-linked polyethylene that is manufactured by a 7.5Mrad irradiation cycle, melt annealing and subsequent ethylene oxide sterilisation. It is manufactured in sizes to accept 32mm and 36mm diameter femoral heads.
Surgical procedure is unilateral. Approximate duration of the surgical procedure time is 70 minutes. Theatre time is 2 hours.
Query!
Intervention code [1]
257270
0
Treatment: Surgery
Query!
Comparator / control treatment
Uncontrolled
Query!
Control group
Uncontrolled
Query!
Outcomes
Primary outcome [1]
259281
0
To evaluate the migration of the E2 Cemented femoral stem and the P2 all-poly cup, in primary cemented total hip replacement using an RSA technique to predict long-term safety and effectiveness of each hip system component from early post operative outcomes in a small cohort of patients.
Query!
Assessment method [1]
259281
0
Query!
Timepoint [1]
259281
0
Subjects will be seen at the 6 month, 1 year, 2 years and 5 years interval post surgery
Query!
Primary outcome [2]
259400
0
To evaluate the in-vivo wear of the P2 cup, in primary cemented total hip replacement using an RSA technique to determine polyethylene wear rates per annum in 3 directions.
Query!
Assessment method [2]
259400
0
Query!
Timepoint [2]
259400
0
Subjects will be seen at the 6 month, 1 year, 2 years and 5 years interval post surgery
Query!
Secondary outcome [1]
265702
0
To estimate the clinical complication rates for the Cemented E2 Total Hip System using clinical evaluations for disease specific scores (Oxford Hip Score) and non-disease specific scores Hip Dysfunction and Oestoarthritis Outcome Score(HOOS) in addition to collation of any adverse events including clinical and radiological underperformance.
Query!
Assessment method [1]
265702
0
Query!
Timepoint [1]
265702
0
Subjects will be seen at the 6 month, 1 year, 2 years and 5 years interval post surgery
Query!
Eligibility
Key inclusion criteria
1.Patient requires unilateral primary total hip arthroplasty due to non- inflammatory degenerative joint disease (e.g. osteoarthritis, traumatic arthritis, avascular necrosis, dysplasia/ developmental dysplasia of the hip (DDH) who are candidates for a Cemented Total Hip System as determined jointly by the surgeon and patient.
2.Male and non-pregnant female patients aged 18 to 75
3.Patients who understand the conditions of the study and are willing and able to give written informed consent to participate in the length of the study including prescribed follow-ups.
Query!
Minimum age
18
Years
Query!
Query!
Maximum age
75
Years
Query!
Query!
Sex
Both males and females
Query!
Can healthy volunteers participate?
No
Query!
Key exclusion criteria
1.Patient has active infection or sepsis (treated or untreated)
2.Patient has any vascular insufficiency, muscular atrophy, or neuromuscular disease severe enough to compromise implant stability or postoperative recovery.
3.Patient is female of child-bearing age and not taking contraceptive precautions
4.Patient has inadequate bone stock to support the device (e.g. severe osteopenia, family history of severe osteoporosis).
5.Patient has inflammatory joint disease (e.g. rheumatoid arthritis)
6.Patient has known moderate to severe renal insufficiency.
7.Patient has a known or suspected metal sensitivity.
8.Patient is immunosuppressed with diseases such as acquired immunodeficiency syndrome (AIDS) or receiving high doses of corticosteroids.
9.Patient has an emotional or neurological condition that would pre-empt their ability or unwillingness to participate in the Clinical Evaluation including mental illness, mental retardation, or drug, alcohol abuse.
10.Patient is severely overweight. Body Mass Index BMI > 40.
Query!
Study design
Purpose of the study
Treatment
Query!
Allocation to intervention
Non-randomised trial
Query!
Procedure for enrolling a subject and allocating the treatment (allocation concealment procedures)
Query!
Methods used to generate the sequence in which subjects will be randomised (sequence generation)
Query!
Masking / blinding
Open (masking not used)
Query!
Who is / are masked / blinded?
Query!
Query!
Query!
Query!
Intervention assignment
Single group
Query!
Other design features
N/A
Query!
Phase
Not Applicable
Query!
Type of endpoint/s
Safety/efficacy
Query!
Statistical methods / analysis
Query!
Recruitment
Recruitment status
Not yet recruiting
Query!
Date of first participant enrolment
Anticipated
1/12/2010
Query!
Actual
Query!
Date of last participant enrolment
Anticipated
Query!
Actual
Query!
Date of last data collection
Anticipated
Query!
Actual
Query!
Sample size
Target
25
Query!
Accrual to date
Query!
Final
Query!
Recruitment in Australia
Recruitment state(s)
Query!
Funding & Sponsors
Funding source category [1]
257711
0
Commercial sector/Industry
Query!
Name [1]
257711
0
Joint Research Pty Ltd
Query!
Address [1]
257711
0
342 Chisholm Road, Auburn NSW 2144
Query!
Country [1]
257711
0
Australia
Query!
Primary sponsor type
Commercial sector/Industry
Query!
Name
Joint Research Pty Ltd
Query!
Address
342 Chisholm Road, Auburn NSW 2144
Query!
Country
Australia
Query!
Secondary sponsor category [1]
256928
0
None
Query!
Name [1]
256928
0
Query!
Address [1]
256928
0
Query!
Country [1]
256928
0
Query!
Ethics approval
Ethics application status
Approved
Query!
Ethics committee name [1]
259750
0
Southern Adelaide Health Service / Flinders University Human Research Ethics Committee
Query!
Ethics committee address [1]
259750
0
Southern Adelaide Health Service SA Health Flinders Medical Centre Flinders Drive, Bedford Park South Australia 5042
Query!
Ethics committee country [1]
259750
0
Australia
Query!
Date submitted for ethics approval [1]
259750
0
15/02/2010
Query!
Approval date [1]
259750
0
15/05/2010
Query!
Ethics approval number [1]
259750
0
67/10
Query!
Summary
Brief summary
The aim of this clinical study is to determine the safety and effectiveness of the cemented Total Hip System (E2 stem/P2 cup). This will be done by collecting information and data on measured outcomes on the Total Hip System, using RSA method to provide early results on the implant. The intended use of this implant is for patients with degenerative joint disease who require a primary total hip replacement.
Query!
Trial website
Query!
Trial related presentations / publications
Query!
Public notes
Query!
Contacts
Principal investigator
Name
31688
0
Prof Jegan Krishnan
Query!
Address
31688
0
Department of Orthopaedics, Flinders Medical Centre, Flinders Drive,
Bedford Park SA 5042
Query!
Country
31688
0
Australia
Query!
Phone
31688
0
+61 08 8204 4289
Query!
Fax
31688
0
Query!
Email
31688
0
[email protected]
Query!
Contact person for public queries
Name
14935
0
Anthony Switzer
Query!
Address
14935
0
Joint Research Pty Ltd
342 Chisholm Road
Auburn
NSW 2144
Query!
Country
14935
0
Australia
Query!
Phone
14935
0
+61 (0)457 733 196
Query!
Fax
14935
0
Query!
Email
14935
0
[email protected]
Query!
Contact person for scientific queries
Name
5863
0
Anthony Switzer
Query!
Address
5863
0
Joint Research Pty Ltd
342 Chisholm Road
Auburn
NSW 2144
Query!
Country
5863
0
Australia
Query!
Phone
5863
0
+61 (0)457 733 196
Query!
Fax
5863
0
Query!
Email
5863
0
[email protected]
Query!
No information has been provided regarding IPD availability
What supporting documents are/will be available?
No Supporting Document Provided
Results publications and other study-related documents
Documents added manually
No documents have been uploaded by study researchers.
Documents added automatically
No additional documents have been identified.
Download to PDF