Please note that the copy function is not enabled for this field.
If you wish to
modify
existing outcomes, please copy and paste the current outcome text into the Update field.
LOGIN
CREATE ACCOUNT
LOGIN
CREATE ACCOUNT
MY TRIALS
REGISTER TRIAL
FAQs
HINTS AND TIPS
DEFINITIONS
Trial Review
The ANZCTR website will be unavailable from 1pm until 3pm (AEDT) on Wednesday the 30th of October for website maintenance. Please be sure to log out of the system in order to avoid any loss of data.
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been endorsed by the ANZCTR. Before participating in a study, talk to your health care provider and refer to this
information for consumers
Download to PDF
Trial registered on ANZCTR
Registration number
ACTRN12613000014752
Ethics application status
Approved
Date submitted
14/12/2012
Date registered
7/01/2013
Date last updated
7/01/2013
Type of registration
Retrospectively registered
Titles & IDs
Public title
Red-Free Light for Measurement of Intraocular Pressure in Healthy Volunteers using Goldmann Applanation Tonometer without Fluorescein
Query!
Scientific title
Red-Free Light for Measurement of Intraocular Pressure in Healthy Volunteers using Goldmann Applanation Tonometer without Fluorescein
Query!
Secondary ID [1]
281688
0
none
Query!
Universal Trial Number (UTN)
Query!
Trial acronym
Query!
Linked study record
Query!
Health condition
Health condition(s) or problem(s) studied:
measurement of intraocular pressure ,a new method
287976
0
Query!
intraocular pressure assessment
287977
0
Query!
Condition category
Condition code
Eye
288360
288360
0
0
Query!
Normal eye development and function
Query!
Intervention/exposure
Study type
Observational
Query!
Patient registry
Query!
Target follow-up duration
Query!
Target follow-up type
Query!
Description of intervention(s) / exposure
Five hundred eyes of 250 patients attending the Ophthalmology Outpatient, Suez Canal University Clinic were measured for intraocular pressure using the same Goldmann applanation tonometer mounted on Haag-Streit Slit Lamp, measurement first were done with red free light without Fluorescein then other measurements were done with cobalt blue light and topical Fluorescein on the same eyes . The measurement for one patient take place in one session and all measurements takes 15 minutes per patient.
Query!
Intervention code [1]
286224
0
Not applicable
Query!
Comparator / control treatment
the same group had two active intervention. the measurement with cobalt blue light and topical fluorescein is the control group.
Query!
Control group
Active
Query!
Outcomes
Primary outcome [1]
288526
0
The Mean Intraocular Pressure {IOP} was 15.23+/- 6.3 (SD) mm Hg using the red free light without Fluorescein while the mean was 15.78 +/- 6. 7 (SD) mm Hg using cobalt blue light and after application of Fluorescein in the conjunctival sac. On paired t test analysis, this difference was not significant.
Query!
Assessment method [1]
288526
0
Query!
Timepoint [1]
288526
0
two months
Query!
Secondary outcome [1]
300513
0
None
Query!
Assessment method [1]
300513
0
Query!
Timepoint [1]
300513
0
None
Query!
Eligibility
Key inclusion criteria
healthy persons attending ophthalmology outpatient clinic
Query!
Minimum age
20
Years
Query!
Query!
Maximum age
60
Years
Query!
Query!
Sex
Both males and females
Query!
Can healthy volunteers participate?
Yes
Query!
Key exclusion criteria
patients with corneal pathology
Query!
Study design
Purpose
Query!
Duration
Query!
Selection
Query!
Timing
Query!
Statistical methods / analysis
Query!
Recruitment
Recruitment status
Completed
Query!
Date of first participant enrolment
Anticipated
3/11/2011
Query!
Actual
3/11/2011
Query!
Date of last participant enrolment
Anticipated
4/01/2012
Query!
Actual
4/01/2012
Query!
Date of last data collection
Anticipated
Query!
Actual
Query!
Sample size
Target
500
Query!
Accrual to date
Query!
Final
Query!
Recruitment in Australia
Recruitment state(s)
Query!
Recruitment outside Australia
Country [1]
4760
0
Egypt
Query!
State/province [1]
4760
0
ismailia
Query!
Funding & Sponsors
Funding source category [1]
286477
0
University
Query!
Name [1]
286477
0
Suez Canal University Hospital
Query!
Address [1]
286477
0
4 km street
Ismailia
postcode 675
ismailia
Query!
Country [1]
286477
0
Egypt
Query!
Primary sponsor type
University
Query!
Name
suez canal university hospital
Query!
Address
Suez Canal University Hospital
4 km street
Ismailia
postcode 675
Query!
Country
Egypt
Query!
Secondary sponsor category [1]
285268
0
None
Query!
Name [1]
285268
0
Query!
Address [1]
285268
0
Query!
Country [1]
285268
0
Query!
Other collaborator category [1]
277228
0
None
Query!
Name [1]
277228
0
none
Query!
Address [1]
277228
0
none
Query!
Country [1]
277228
0
Egypt
Query!
Ethics approval
Ethics application status
Approved
Query!
Ethics committee name [1]
288555
0
suez canal university ethics commetti
Query!
Ethics committee address [1]
288555
0
Suez CanalUniversity Ethics commetti Suez Canal University 4 km street Postcode 4356 Ismailia
Query!
Ethics committee country [1]
288555
0
Egypt
Query!
Date submitted for ethics approval [1]
288555
0
05/10/2011
Query!
Approval date [1]
288555
0
09/11/2011
Query!
Ethics approval number [1]
288555
0
5643
Query!
Summary
Brief summary
Abstract Purpose: To evaluate the use of red free light in the measurement of intraocular pressure using a Goldmann applanation tonometer without Fluorescein. Materials and Methods: Five hundred eyes of 250 patients attending the Ophthalmology Outpatient, Suez Canal University Clinic were measured for intraocular pressure using the same Goldmann applanation tonometer mounted on Haag-Streit Slit Lamp, measurement first were done with red free light without Fluorescein then other measurements were done with cobalt blue light and topical Fluorescein on the same eyes . Results: The Mean IOP was 15.23+/- 6.3 (SD) mm Hg using the red free light without Fluorescein while the mean was 15.78 +/- 6. 7 (SD) mm Hg using cobalt blue light and after application of Fluorescein in the conjunctival sac. On paired t test analysis, this difference was not significant. Conclusion: Measurement of IOP with Goldmann appanation tonometer with red free light without the use of Fluorescein is easy, simple, save time and give an accurate IOP measurement compared to traditional measurement with cobalt blue light and topical Fluorescein.
Query!
Trial website
Query!
Trial related presentations / publications
Query!
Public notes
Query!
Contacts
Principal investigator
Name
36666
0
A/Prof ehab ghoneim
Query!
Address
36666
0
el tammeem street
borg el harameen
6th floor
Zip code 323
portfoad
portsaid
Query!
Country
36666
0
Egypt
Query!
Phone
36666
0
00201223639848
Query!
Fax
36666
0
0020663408822
Query!
Email
36666
0
[email protected]
Query!
Contact person for public queries
Name
36667
0
ehab ghoneim
Query!
Address
36667
0
el tammeem street
borg el harameen
6th floor
Zip tcode 323
portfoad
portsaid
Query!
Country
36667
0
Egypt
Query!
Phone
36667
0
00201223639848
Query!
Fax
36667
0
0020663408822
Query!
Email
36667
0
[email protected]
Query!
Contact person for scientific queries
Name
36668
0
ehab ghoneim
Query!
Address
36668
0
el tammeem street
borg el harameen
6th floor
Zip code 323
portfoad
portsaid
Query!
Country
36668
0
Egypt
Query!
Phone
36668
0
00201223639848
Query!
Fax
36668
0
0020663408822
Query!
Email
36668
0
[email protected]
Query!
No information has been provided regarding IPD availability
What supporting documents are/will be available?
No Supporting Document Provided
Results publications and other study-related documents
Documents added manually
No documents have been uploaded by study researchers.
Documents added automatically
No additional documents have been identified.
Download to PDF