Please note that the copy function is not enabled for this field.
If you wish to
modify
existing outcomes, please copy and paste the current outcome text into the Update field.
LOGIN
CREATE ACCOUNT
LOGIN
CREATE ACCOUNT
MY TRIALS
REGISTER TRIAL
FAQs
HINTS AND TIPS
DEFINITIONS
Trial Review
The ANZCTR website will be unavailable from 1pm until 3pm (AEDT) on Wednesday the 30th of October for website maintenance. Please be sure to log out of the system in order to avoid any loss of data.
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been endorsed by the ANZCTR. Before participating in a study, talk to your health care provider and refer to this
information for consumers
Download to PDF
Trial registered on ANZCTR
Registration number
ACTRN12617001151325
Ethics application status
Approved
Date submitted
25/07/2017
Date registered
7/08/2017
Date last updated
7/08/2017
Type of registration
Retrospectively registered
Titles & IDs
Public title
Comparison of neuromuscular monitorings (TOF-Watch SX stabilised in the SL TOF tube versus Philips NMT Module stabilised in Philips Hand Adaptor ) in patients undergoing rhinoplasty or rhinoseptoplasty.
Query!
Scientific title
Investigation protocol comparing two quantitative modules for monitoring peroperative neuromuscular transmission in patients undergoing rhinoplasty or rhinoseptoplasty Under general anaesthesic: TOF-Watch SX stabilised in the SL TOF tube versus Philips NMT module stabilised in Philips Hand Adaptor .
Query!
Secondary ID [1]
291927
0
None
Query!
Universal Trial Number (UTN)
None
Query!
Trial acronym
None
Query!
Linked study record
None
Query!
Health condition
Health condition(s) or problem(s) studied:
patients undergoing rhinoplasty or rhinoseptoplasty under general anaesthesic
303254
0
Query!
Condition category
Condition code
Anaesthesiology
302676
302676
0
0
Query!
Anaesthetics
Query!
Intervention/exposure
Study type
Observational
Query!
Patient registry
False
Query!
Target follow-up duration
Query!
Target follow-up type
Query!
Description of intervention(s) / exposure
This investigation protocol seeks to compare the results obtained in clinical practice in curarised patients using two monitoring modules currently marketed (in line with EU standards):
The results obtained simultaneously by the Philips Intellivue NMT module (Philips, The Netherlands) on a patient's hand stabilised in Philips Hand Adaptor will be compared with those obtained by the TOF-Watch SX (Organon, The Netherlands) fitted to their other hand also stabilised in the SL TOF tube, an association which has demonstrated the adequacy of its results compared with mechanomyography, the established reference method. The investigation focusses on a cohort of 30 patients aged 18 to 80, classified ASA I or II and undergoing rhinoplasty or rhinoseptoplasty under general anaesthetic. The patient's height, weight, age and sex are recorded in the protocol, as is their dominant hand (left or right) to define the population investigated.
As premedication, the patient receives Alprazolam 0.5 mg an hour before they go to theatre. On arrival in theatre, the patient is conventionally monitored with a saturometer, an electrocardiogram with three or five derivations depending on their antecedents, and their blood pressure is measured non-invasively, scheduled in automatic mode with constant measurements at five-minute intervals.
An intravenous drip (18G catheter) is inserted into their forearm or elbow, for intravenous perfusion of Plasmalyte 500 ml as the first perfusion.
The module to monitor neuromuscular transmission using acceleromyography is connected (non-invasive and non-traumatic), one hand with TOF-Watch SX stabilised in SL TOF tube, the other one with NMT Philips in Philips Hand Adaptor. We observe the criteria for good clinical practice for pharmaco-dynamic investigations as proposed by Fuchs-Buder. The skin is cleaned with diethylether and two ECG skin electrodes are placed along the route of the ulnar nerve on each wrist.
The arm on which the Philips Intellivue NMT module is placed to a hand stabilised in Philips Hand Adaptor (in contrast to a previous trial which was left free of any specific installation as recommended in its user manual), whilst the forearm on which the AMG TOF-Watch SX is placed is positioned in the SL TOF Tube and this is thus considered the reference curarisation monitoring module.
The arms are then placed alongside the body in "spoon"-type arm supports with a thick layer of gel to protect nerve structures.
Once all monitoring modules are in place, the patient is pre-oxygenated using pure oxygen, FiO2 100% at a rate of 8 l/min.
The general anaesthetic is induced with continuous intravenous infusion of Remifentanyl 0.25 gamma/kg/min, and continuous infusion of Propofol 1% to obtain a theoretical plasma concentration of 3 to 4 gamma/cc (Diprifusor Cardinal Health, Basingstoke, UK) and Linisol 2% 1 mg/kg as an intravenous bolus. As soon as the patient loses consciousness, they are manually ventilated.
Now, simultaneously with each NMT monitoring module, we can automatically investigate the supra-maximum stimulation threshold and 100% calibration of initial responses. The amperages determined by the two devices (± 50 mA) are recorded.
Each ulnar nerve is stimulated simultaneously using a Train of Four (4 electric stimulations at 2 Hz, Train of Four, TOF) repeated at 15-second intervals.
Four successive base value measurements for the TOF ratio (T4/T1 ratio) are recorded for each curarisation monitoring module, simultaneously, and their averages determine the reference values before curarisation. We calculate 90% of this base value to determine the neuromuscular blocking recovery threshold for each monitoring module using the following formula:
Normalised TOF ratio 90% = sum of 4 TOF ratio × 9/40 with a result rounded up.
With the baseline determined, the patient is curarised with administration of rocuronium 0.5 mg/kg. The theatre time is noted as the reference time (hh:mm:ss). Non-invasive automatic blood pressure measurement is suspended during the neuromuscular blocking induction phase so as not to limit the distribution of the Rocuronium in either of the two arms.
So we expect to each a state of deep curarisation, with a TOF count of 0. Again, the exact time is recorded when the TOF count of 0 is reached using the TOF-Watch and when it is reached using the Philips NMT (onset duration).
Then non-invasive blood pressure measurement is reactivated.
The patient is then conventionally intubated, eye protection is put in place, the tube is fitted and assisted ventilation in "Controlled volume" mode is begun, followed by the surgical equipment.
Post-Tetanic-Count (PTC: automatic stimulation sequence including 50 Hz tetanic stimulation for 5 seconds adapted to monitor deep neuromuscular blocking) is then measured with each monitoring module at the same time (hours - minutes -seconds noted). After a free period of 3 minutes, TOF stimulation mode is launched every 15 seconds.
Anaesthesia is maintained with continuous intravenous administration of Remifentanyl 0.15 gamma/kg/min and Propofol 1% in AIVOC mode with a target plasma concentration of 2 to 4 gamma/cc. Neither Magnesium, nor halogenated vapour, nor a further bolus of rocuronium is administered (to prevent potentialisation of neuromuscular blocking by these agents).
We then continuously observe via the TOF spontaneous recovery of neuromuscular blocking with successive, simultaneous measurements (every 15 seconds) using the two curarisation monitoring modules.
The investigation seeks to confirm (or otherwise) the similarity between the results obtained using each monitoring module positioned in the SL TOF tube.
Query!
Intervention code [1]
298046
0
Diagnosis / Prognosis
Query!
Comparator / control treatment
Neuromuscular monitoring comparison : Philips NMT module stabilised in Philips Hand Adaptor compared with TOF-Watch SX stabilised in SL TOF tube (considered the reference).
Query!
Control group
Active
Query!
Outcomes
Primary outcome [1]
302884
0
Initial TOF ratios are recorded with 4 successive measurements before rocuronium is administrered. The average of the 4 measurements determines the initial Baseline. These baselines obtained by the Philips NMT module and the TOF-Watch SX are compared for each patient.
Query!
Assessment method [1]
302884
0
Query!
Timepoint [1]
302884
0
As soon as the patient loses consciousness, they are manually ventilated. Simultaneously with each NMT monitoring module, we can automatically investigate the supra-maximum stimulation thresold and 100% calibration of initial responses. The ampérages determined by the two devices (+/- 50 mA) are recorded. Each ulnar nerve is stimulated simultaneously, repeated at 15-second intervals for the duration of the surgery.
Query!
Secondary outcome [1]
337333
0
TOF ratio 90% are recorded on each device and they are compared.
Query!
Assessment method [1]
337333
0
Query!
Timepoint [1]
337333
0
As soon as the patient loses consciousness, they are manually ventilated. Simultaneously with each NMT monitoring module, we can automatically investigate the supra-maximum stimulation thresold and 100% calibration of initial responses. The ampérages determined by the two devices (+/- 50 mA) are recorded. Each ulnar nerve is stimulated simultaneously, repeated at 15-second intervals for the duration of the surgery.
Query!
Eligibility
Key inclusion criteria
- aged 18 to 80
- classified ASA I or II
- undergoing rhinoplasty or rhinoseptoplasty under general anaesthetic
Query!
Minimum age
18
Years
Query!
Query!
Maximum age
80
Years
Query!
Query!
Sex
Both males and females
Query!
Can healthy volunteers participate?
Yes
Query!
Key exclusion criteria
- pregnant and breastfeeding women,
- patients with renal or hepatic insufficiency,
- patients with neurological deficit,
- patients with a suspected allergy to the drugs used in the protocol or receiving treatment which will interfere with neuromuscular transmission
Query!
Study design
Purpose
Screening
Query!
Duration
Cross-sectional
Query!
Selection
Defined population
Query!
Timing
Prospective
Query!
Statistical methods / analysis
Baseline analysis: definition and comparison of levels and repeatability factors.
Initial TOF ratios are recorded with 4 successive measurements before rocuronium is administered. The average of the 4 measurements determines the initial baseline. These baselines obtained by the Philips NMT module and the TOF-Watch SX are compared for each patient using a Wilcoxon Rank Sum test. Repeatability factors (1.96v2 SD) are compared using a z test, a low factor indicating little variability between consecutive measurements. P<0.05 is considered significant.
The same comparative analysis is conducted once a final baseline has stabilised, ensured with administration of 100 mg of Sugammadex after recovery of a normalised TOF ratio of 90%. The initial and final baselines will be compared using a Wilcoxon Rank Sum test. P<0.05 is considered significant.
Analysis of neuromuscular blocking recovery profiles: performance of the Philips NMT module compared with the TOF-Watch SX (considered the reference).
In the different neuromuscular blocking scores (PTC, TOF count 2, TOF ratio 50%, TOF ratio 90% and normalised TOF ratio 90%), 4 consecutive, simultaneous measurements are recorded on each device when the value concerned is reached on the TOF-Watch SX, but also when the TOF ratio 90% (gross and normalised) is reached with the Philips NMT module. These results are compared using a Wilcoxon Rank Sum test, p<0.05 significant. The bias and the agreement limits of the two devices with different scores considered are also determined using the method described by Bland and Altman.
Sample determination is considered in light of recovery of the TOF ratio 90%, the critical safety threshold for orotracheal extubation.
Considering a risk alpha of 0.05 and a power 1-beta of 95, and for variability (DS) observed on a pre-series of 17.5%, we must recruit 30 patients so that a difference of 10% using the two measurements does not escape us.
The statistical analyses were carried out with SPSS Registered Trademark 15.0 statistical software (SPSS Inc., Chicago, Ill) and G*Power 3.
Query!
Recruitment
Recruitment status
Recruiting
Query!
Date of first participant enrolment
Anticipated
Query!
Actual
25/07/2017
Query!
Date of last participant enrolment
Anticipated
27/09/2017
Query!
Actual
Query!
Date of last data collection
Anticipated
28/09/2017
Query!
Actual
Query!
Sample size
Target
30
Query!
Accrual to date
10
Query!
Final
Query!
Recruitment outside Australia
Country [1]
9092
0
Belgium
Query!
State/province [1]
9092
0
Namur
Query!
Funding & Sponsors
Funding source category [1]
296432
0
Hospital
Query!
Name [1]
296432
0
CHU UCL Namur - Mont-Godinne
Query!
Address [1]
296432
0
Gaston Therasse Street, 1
5530 Yvoir
Query!
Country [1]
296432
0
Belgium
Query!
Primary sponsor type
Hospital
Query!
Name
CHU UCL Namur - Mont-Godinne
Query!
Address
Gaston Therasse Street, 1
5530 Yvoir
Query!
Country
Belgium
Query!
Secondary sponsor category [1]
295385
0
None
Query!
Name [1]
295385
0
Query!
Address [1]
295385
0
Query!
Country [1]
295385
0
Query!
Ethics approval
Ethics application status
Approved
Query!
Ethics committee name [1]
297661
0
Ethics Committe of CHU UCL Namur
Query!
Ethics committee address [1]
297661
0
Gaston Therasse Street, 1 5530 Yvoir
Query!
Ethics committee country [1]
297661
0
Belgium
Query!
Date submitted for ethics approval [1]
297661
0
05/05/2017
Query!
Approval date [1]
297661
0
11/07/2017
Query!
Ethics approval number [1]
297661
0
B039201732792
Query!
Summary
Brief summary
The reliability of monitoring of neuromuscular transmission used during surgery requiring curarisation (or neuromuscular blocking) is key to ensuring patient safety and optimum operating conditions. However, in clinical practice, the results obtained using devices provided by the industry are not always credible. This investigation protocol seeks to compare the results obtained in clinical practice in curarised patients using two monitoring modules currently marketed (in line with EU standards): The results obtained simultaneously by the Philips Intellivue NMT module (Philips, The Netherlands) on a patient's hand stabilised in Philips Hand Adaptor will be compared with those obtained by the TOF-Watch SX (Organon, The Netherlands) fitted to their other hand stabilised in the SL TOF tube, an association which has demonstrated the adequacy of its results compared with mechanomyography, the established reference method. In fact, although they use the same measuring principle (acceleromyography), the results obtained using the two devices appear to be quite different, especially during the final phase of recovery from neuromuscular blocking. Confirmation of a minimum recovery threshold (TOF ratio 90%) is essential if we are to rule out any residual curarisation and provide patients with optimum conditions of safety during tracheal extubation and when waking them. Any significant difference (more than 10%) between the inherent results obtained using the two devices would have significant clinical implications. In fact, recovery of the TOF ratio 80% is quite insufficient in comparison at 90%
Query!
Trial website
Query!
Trial related presentations / publications
Query!
Public notes
Query!
Contacts
Principal investigator
Name
74742
0
Dr Dubois Virginie
Query!
Address
74742
0
CHU UCL Namur Godinne
Gaston Therasse Street, 1
5530 Yvoir
Query!
Country
74742
0
Belgium
Query!
Phone
74742
0
+32 81 423910
Query!
Fax
74742
0
Query!
Email
74742
0
[email protected]
Query!
Contact person for public queries
Name
74743
0
Fostier Guillaume
Query!
Address
74743
0
CHU UCL Namur Godinne
Gaston Therasse Street, 1
5530 Yvoir
Query!
Country
74743
0
Belgium
Query!
Phone
74743
0
+32 81 423911
Query!
Fax
74743
0
Query!
Email
74743
0
[email protected]
Query!
Contact person for scientific queries
Name
74744
0
Dubois Philippe
Query!
Address
74744
0
CHU UCL Namur Godinne
Gaston Therasse Street, 1
5530 Yvoir
Query!
Country
74744
0
Belgium
Query!
Phone
74744
0
+32 81 423929
Query!
Fax
74744
0
Query!
Email
74744
0
[email protected]
Query!
No information has been provided regarding IPD availability
What supporting documents are/will be available?
No Supporting Document Provided
Results publications and other study-related documents
Documents added manually
No documents have been uploaded by study researchers.
Documents added automatically
No additional documents have been identified.
Download to PDF