Trial Review
The ANZCTR website will be unavailable from 1pm until 3pm (AEDT) on Wednesday the 30th of October for website maintenance. Please be sure to log out of the system in order to avoid any loss of data.
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been endorsed by the ANZCTR. Before participating in a study, talk to your health care provider and refer to this
information for consumers
Download to PDF
Trial registered on ANZCTR
Registration number
ACTRN12617000819325
Ethics application status
Approved
Date submitted
31/05/2017
Date registered
5/06/2017
Date last updated
19/11/2018
Date data sharing statement initially provided
19/11/2018
Type of registration
Prospectively registered
Titles & IDs
Public title
An evaluation of a new contact lens design against two prototype designs and a commercially-available single vision design
Query!
Scientific title
Prospective, double-masked, bilateral wear, crossover, dispensing clinical trial to compare the visual performance between a new commercially-available contact lens design which utilise digital zone optics, prototype contact lens designs which utilise higher-order spherical aberrations to increase depth-of-focus and a commercially-available single vision contact lens
Query!
Secondary ID [1]
292093
0
None
Query!
Universal Trial Number (UTN)
Query!
Trial acronym
The DZO Trial
Query!
Linked study record
Query!
Health condition
Health condition(s) or problem(s) studied:
Myopia
303511
0
Query!
Condition category
Condition code
Eye
302926
302926
0
0
Query!
Diseases / disorders of the eye
Query!
Intervention/exposure
Study type
Interventional
Query!
Description of intervention(s) / exposure
This trial will be a prospective, bilateral, randomised, double-masked, cross-over clinical trial.
Participants will wear four lens types for 5 consecutive days on a single-use, daily wear basis with a minimum two day wash-out between lens types. The four lens types comprise:
Commercially-available single vision lenses made from comfilcon A: Base curve = 8.6 mm, Diameter = 14 mm, Power Range = -0.75 to -6.00 D
Commercially-available lenses utilizing digital zone optics made from comfilcon A: Base curve = 8.6 mm, Diameter = 14 mm, Power Range = -0.75 to -6.00 D
Two prototype extended depth of focus (EDOF) which utilize deliberate manipulation of multiple higher-order spherical aberrations terms to extend depth of focus made from Poly-HEMA material. Base curve = 8.4 mm, Diameter = 14 mm, Power Range = -0.75 to -6.00 D
Minimum wearing time will be 5 days and 6 hours/day with no maximum wearing time provided lenses are not slept in overnight.
There will 9 visits comprising Baseline and two visits for each of the 4 lens designs (Fitting and Assessment). Each visit will be approximately 45 minutes in duration.
Baseline visits will comprise auto-refraction, subjective refraction with visual acuity measurement and ocular assessment with a slit-lamp biomicroscope (a specialized microscope for viewing the eye).
Fitting visits will be performed by unmasked investigators and comprise contact lens fitting, assessment of contact lens visual acuity and assessment of contact lenses on eye with a slit-lamp biomicroscope (a specialized microscope for viewing the eye).
Assessment visits will be performed by masked investigators and comprise assessment of contact lens visual acuity, distance and near heterophoria, monocular accommodative facility and subjective ratings of vision questionnaire utilizing a 1-10 numeric rating scale, and the validated Computer Vision syndrome Questionnaire.
In between Fitting and Assessment visits, participants will complete a subjective ratings of vision take-home questionnaire utilizing a 1-10 numeric rating scale.
A minimum 2-day wash-out will be observed between Fitting and Assessment visits where study lenses are not worn. Participants will wear their habitual vision correction in between wearing study lenses
All contact lenses will be prescribed and all assessments will be carried out by an optometrist. Participants will be instructed to return all unused contact lenses.
Query!
Intervention code [1]
298235
0
Treatment: Devices
Query!
Comparator / control treatment
Active control (single vision comfilcon A lenses)- crossover study
Query!
Control group
Active
Query!
Outcomes
Primary outcome [1]
302319
0
Visual acuity: This will be assessed using electronic logMAR charts at 6 m, 70 cm and 40 cm.
Query!
Assessment method [1]
302319
0
Query!
Timepoint [1]
302319
0
All 4 assessment visits
Query!
Secondary outcome [1]
335468
0
Subjective ratings of vision: These will be assessed with a questionnaire utilising numeric rating scales (1-10 in 1-point steps) which assess clarity of vision and ghosing at distance, intermediate and near, vision when driving during day time and night time and overall vision satisfaction.
Query!
Assessment method [1]
335468
0
Query!
Timepoint [1]
335468
0
All 4 midpoints between Fitting and Assessment visits
Query!
Secondary outcome [2]
335469
0
Subjective ratings of vision: These will be assessed with a questionnaire utilising numeric rating scales (1-10 in 1-point steps) which assess clarity of vision and ghosing at distance, intermediate and near, vision when driving during day time and night time and overall vision satisfaction.
Query!
Assessment method [2]
335469
0
Query!
Timepoint [2]
335469
0
All 4 Assessment Visits
Query!
Secondary outcome [3]
335550
0
Distance heterophoria: This will be assessed with a Distance Howell Phoria Card at 3 m
Query!
Assessment method [3]
335550
0
Query!
Timepoint [3]
335550
0
All 4 Assessment Visits.
Query!
Secondary outcome [4]
335551
0
Near monocular accommodative facility: This will be assessed with +/-2.00 D flip spheres at 33 cm, with the left eye occluded.
Query!
Assessment method [4]
335551
0
Query!
Timepoint [4]
335551
0
All 4 Assessment Visits.
Query!
Secondary outcome [5]
335552
0
Presence of computer vision sydrome: This will be assessed with the validated Compuer Vision Syndrom Questionnaire.
Query!
Assessment method [5]
335552
0
Query!
Timepoint [5]
335552
0
All 4 Assessment Visits.
Query!
Eligibility
Key inclusion criteria
Able to read and comprehend English and give informed consent as demonstrated by signing a record of informed consent.
Be between 18-40 years old, male or female.
Willing to comply with the wearing and clinical trial visit schedule as directed by the Investigator.
Have ocular health findings considered to be “normal” and which would not prevent the participant from safely wearing contact lenses.
Is myopic and correctable to at least 6/12 (20/40) or better in each eye with contact lenses.
Be suitable and willing to wear contact lenses.
Query!
Minimum age
18
Years
Query!
Query!
Maximum age
40
Years
Query!
Query!
Sex
Both males and females
Query!
Can healthy volunteers participate?
No
Query!
Key exclusion criteria
Any pre-existing ocular irritation, injury or condition (including infection or disease) of the cornea, conjunctiva or eyelids that would preclude contact lens fitting and safe wearing of contact lenses.
Any systemic disease that adversely affects ocular health e.g. diabetes, Graves disease, and auto immune diseases such as ankylosing spondylitis, multiple sclerosis, Sjogrens syndrome and systemic lupus erythematosus. Conditions such as systemic hypertension and arthritis do not automatically exclude prospective participants.
Use of or a need for concurrent category S3 and above ocular medication at enrolment and/or during the clinical trial.
Use of or a need for any systemic medication or topical medications which may alter normal ocular findings / are known to affect a participant’s ocular health / physiology or contact lens performance either in an adverse or beneficial manner at enrolment and/or during the clinical trial.
NB: Systemic antihistamines are allowed on an “as needed basis”, provided they are not used prophylactically during the trial and at least 24 hours before the clinical trial product is used.
Eye surgery within 12 weeks immediately prior to enrolment for this trial.
Previous corneal refractive surgery.
Contraindications to contact lens wear.
Known allergy or intolerance to ingredients in any of the clinical trial products.
Currently enrolled in another clinical trial.
Pregnancy*.
The Investigator may, at his/her discretion, exclude anyone who they believe may not be able to fulfil the clinical trial requirements or it is believed to be in the participant’s best interests.
*Formal testing of pregnancy is not required. A participant’s verbal report is sufficient.
Query!
Study design
Purpose of the study
Treatment
Query!
Allocation to intervention
Randomised controlled trial
Query!
Procedure for enrolling a subject and allocating the treatment (allocation concealment procedures)
Central randomisation by computer
Query!
Methods used to generate the sequence in which subjects will be randomised (sequence generation)
Simple randomisation using a randomisation table created through www.randomization.com
Query!
Masking / blinding
Blinded (masking used)
Query!
Who is / are masked / blinded?
The people receiving the treatment/s
The people assessing the outcomes
Query!
Query!
Query!
Query!
Intervention assignment
Crossover
Query!
Other design features
None
Query!
Phase
Not Applicable
Query!
Type of endpoint/s
Efficacy
Query!
Statistical methods / analysis
Sample size: A minimum of 30 participants are required in order to demonstrate a statistically significant paired difference between lens designs in visual acuity of 0.1 +/- 0.15 logMAR units and subjective ratings of 1 +/- 1.8 units at the 5% level of significance and 80% power. The sample size of 30 participants is adjusted for a low drop out of 10%.
Analysis: Visual acuity will be recorded on a logMAR scale. Data will be summarised as means +/- standard deviations. No transformation is likely to be required. Visual acuity will be compared between each lens design and control lens types. The significance of lens design will be determined for each visit. Repeated effects linear mixed model with subject random intercepts or paired t tests will be employed for the analysis of visual acuity.
Query!
Recruitment
Recruitment status
Completed
Query!
Date of first participant enrolment
Anticipated
7/08/2017
Query!
Actual
20/11/2017
Query!
Date of last participant enrolment
Anticipated
1/03/2018
Query!
Actual
15/03/2018
Query!
Date of last data collection
Anticipated
14/03/2018
Query!
Actual
17/05/2018
Query!
Sample size
Target
35
Query!
Accrual to date
Query!
Final
35
Query!
Recruitment in Australia
Recruitment state(s)
NSW
Query!
Funding & Sponsors
Funding source category [1]
296624
0
Other
Query!
Name [1]
296624
0
Brien Holden Vision Institute
Query!
Address [1]
296624
0
Level 5, Rupert Myers Building Gate 14, Barker
Street University of New South Wales, NSW
2052
Query!
Country [1]
296624
0
Australia
Query!
Primary sponsor type
Charities/Societies/Foundations
Query!
Name
Brien Holden Vision Institute
Query!
Address
Level 4, Rupert Myers Building Gate 14, Barker
Street University of New South Wales, NSW
2052
Query!
Country
Australia
Query!
Secondary sponsor category [1]
295588
0
None
Query!
Name [1]
295588
0
Query!
Address [1]
295588
0
Query!
Country [1]
295588
0
Query!
Ethics approval
Ethics application status
Approved
Query!
Ethics committee name [1]
297857
0
Bellberry Limited
Query!
Ethics committee address [1]
297857
0
129 Glen Osmond Rd Eastwood South Australia 5063
Query!
Ethics committee country [1]
297857
0
Australia
Query!
Date submitted for ethics approval [1]
297857
0
08/05/2017
Query!
Approval date [1]
297857
0
06/06/2017
Query!
Ethics approval number [1]
297857
0
Query!
Summary
Brief summary
The purpose of this study is to compare the visual performance (defined by visual acuity measurements and subjective ratings0 between a new commercially-available contact lens design which utilise digital zone optics (DZO), two prototype Extended Depth-of-Focus (EDOF) contact lens designs which utilise higher-order spherical aberration terms and a commercially-available single vision contact lens (SV). To achieve this, participants will wear each of the 4 lens designs for a minimum of 5 days. Outcome measures will comprise visual acuity and subjective ratings. Our hypotheses are there will be no difference between lens designs for either visual acuity or subjective ratings.
Query!
Trial website
Query!
Trial related presentations / publications
Query!
Public notes
Query!
Contacts
Principal investigator
Name
75282
0
Mr Daniel Tilia
Query!
Address
75282
0
Level 5, Rupert Myers Building Gate 14, Barker
Street University of New South Wales, NSW
2052
Query!
Country
75282
0
Australia
Query!
Phone
75282
0
+61293857516
Query!
Fax
75282
0
+61293857401
Query!
Email
75282
0
[email protected]
Query!
Contact person for public queries
Name
75283
0
Daniel Tilia
Query!
Address
75283
0
Level 5, Rupert Myers Building Gate 14, Barker
Street University of New South Wales, NSW
2052
Query!
Country
75283
0
Australia
Query!
Phone
75283
0
+61293857516
Query!
Fax
75283
0
+61293857401
Query!
Email
75283
0
[email protected]
Query!
Contact person for scientific queries
Name
75284
0
Daniel Tilia
Query!
Address
75284
0
Level 5, Rupert Myers Building Gate 14, Barker
Street University of New South Wales, NSW
2052
Query!
Country
75284
0
Australia
Query!
Phone
75284
0
+61293857516
Query!
Fax
75284
0
+93857401
Query!
Email
75284
0
[email protected]
Query!
Data sharing statement
Will individual participant data (IPD) for this trial be available (including data dictionaries)?
No
Query!
No/undecided IPD sharing reason/comment
Individual participant data will not published. However trial results, recorded as group means plus/minus
SD and their statistical analysis may be published in scientific journals or conferences.
Query!
What supporting documents are/will be available?
No Supporting Document Provided
Results publications and other study-related documents
Documents added manually
No documents have been uploaded by study researchers.
Documents added automatically
No additional documents have been identified.
Download to PDF