Please note that the copy function is not enabled for this field.
If you wish to
modify
existing outcomes, please copy and paste the current outcome text into the Update field.
LOGIN
CREATE ACCOUNT
LOGIN
CREATE ACCOUNT
MY TRIALS
REGISTER TRIAL
FAQs
HINTS AND TIPS
DEFINITIONS
Trial Review
The ANZCTR website will be unavailable from 1pm until 3pm (AEDT) on Wednesday the 30th of October for website maintenance. Please be sure to log out of the system in order to avoid any loss of data.
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been endorsed by the ANZCTR. Before participating in a study, talk to your health care provider and refer to this
information for consumers
Download to PDF
Trial registered on ANZCTR
Registration number
ACTRN12618000075280
Ethics application status
Approved
Date submitted
29/12/2017
Date registered
18/01/2018
Date last updated
18/01/2018
Type of registration
Retrospectively registered
Titles & IDs
Public title
Exploring the impact of chronic obstructive pulmonary disease (COPD) patient characteristics on inhaler device capability and inhaler device characteristics on treatment efficacy.
Query!
Scientific title
Does limited inspiratory capacity in severe COPD impair clinical efficacy of breath-actuated inhaled medication?
Query!
Secondary ID [1]
293695
0
Nil known
Query!
Universal Trial Number (UTN)
U1111-1207-0649
Query!
Trial acronym
Query!
Linked study record
Query!
Health condition
Health condition(s) or problem(s) studied:
COPD
306024
0
Query!
Condition category
Condition code
Respiratory
305176
305176
0
0
Query!
Chronic obstructive pulmonary disease
Query!
Intervention/exposure
Study type
Interventional
Query!
Description of intervention(s) / exposure
Part of the trial is observational and part interventional.
Observational component: measurement of baseline characteristics at the start of a hospital admission for COPD exacerbation and assessing inhaler technique on admission and again at 6 weeks
Interventional component: the trial is single blind (investigator), randomised cross-over trial. Stable, severe COPD patients are randomised to a sequence of inhaler devices (starting with Accuhaler or metered dose inhaler/spacer) delivering the same dose of medication (fluticasone propionate/salmeterol xinafoate SFC 500/50mcg, twice daily). The Accuhaler (also marketed as Diskus) is a round-shaped inhaler that the patient's often liken to a "spaceship" in appearance. The metered dose inhaler is the most commonly used "puffer" type recognised in the lay community. The Accuhaler is a type of dry powder inhaler (DPI) and is breath-actuated. For breath-actuated devices, the patient must generate sufficient inspiratory flow to overcome the intrinsic device resistance for effective actuation and drug deposition. Inherent resistance, and hence inspiratory flow requirement, varies by device. For the metered dose inhaler actuation is part of the device's own function and so this device is much less dependent on inspiratory flow rates. However, for this device, the coordination of actuation and inhalation is critical, and this problem can be largely overcome by using a volumatic spacer or "spacer". Hence, for both devices inhaler technique is important but for the Accuhaler, the patient must generate sufficient inspiratory flow to overcome the device's intrinsic resistance.
After each of two consecutive six week exposure periods study outcomes are assessed. There is no washout between the two treatment exposures (the medication used in each treatment exposure is identical - the treatment exposure differ only in terms of the device used). The primary outcome is quality of life score via the Saint George Respiratory Questionnaire and secondary outcomes include exercise endurance (via the six minute walk test) and complex lung function testing. Treatment adherence is not formally assessed in this study, although inhaler technique, an aspect of treatment adherence, is assessed at baseline and prior to each six week exposure period.
Query!
Intervention code [1]
299947
0
Treatment: Devices
Query!
Intervention code [2]
300018
0
Treatment: Drugs
Query!
Comparator / control treatment
The observational component is uncontrolled.
The interventional component is a cross over study - subjects act as their own controls, as they sequence through the two device interventions
Query!
Control group
Active
Query!
Outcomes
Primary outcome [1]
304332
0
Quality of life score via Saint George Respiratory Questionnaire (total score)
Query!
Assessment method [1]
304332
0
Query!
Timepoint [1]
304332
0
Assessed at baseline, 6 and 12 weeks post randomisation
Query!
Secondary outcome [1]
341610
0
Six minute walk test distance
Query!
Assessment method [1]
341610
0
Query!
Timepoint [1]
341610
0
Assessed at baseline, 6 and 12 weeks post randomisation
Query!
Secondary outcome [2]
341611
0
Forced expiratory volume in one second - using spirometry
Query!
Assessment method [2]
341611
0
Query!
Timepoint [2]
341611
0
Assessed at baseline, 6 and 12 weeks post randomisation
Query!
Secondary outcome [3]
341901
0
Forced vital capacity, assessed using spirometry
Query!
Assessment method [3]
341901
0
Query!
Timepoint [3]
341901
0
Assessed at baseline, 6 and 12 weeks post randomisation
Query!
Secondary outcome [4]
341903
0
Inspiratory muscle strength, assessed using measurement of maximal inspiratory pressure (MIP). MIP was measured using standard lung function testing equipment according to American Thoracic Society/ European Respiratory Society guidelines published in 2002. The lung function testing equipment is not solely used for measurement of MIP (eg also used for plethysmography, spirometry) but the most relevant components include a mouthpiece, a pressure transducer (to record the maximal generated inspiratory pressure) and a "closed" circuit with a small amount of incorporated leak (to prevent falsely low recordings due to unintentional glottic closure by the subject).
Query!
Assessment method [4]
341903
0
Query!
Timepoint [4]
341903
0
Assessed at baseline, 6 and 12 weeks post randomisation
Query!
Secondary outcome [5]
341904
0
residual volume, assessed using plethysmography
Query!
Assessment method [5]
341904
0
Query!
Timepoint [5]
341904
0
Assessed at baseline, 6 and 12 weeks post randomisation
Query!
Eligibility
Key inclusion criteria
Age 40 or more years, moderate to severe COPD diagnosed clinically and on spirometry
Query!
Minimum age
40
Years
Query!
Query!
Maximum age
No limit
Query!
Query!
Sex
Both males and females
Query!
Can healthy volunteers participate?
No
Query!
Key exclusion criteria
COPD exacerbation within 6 weeks
psychosocial circumstances or physical health preventing informed consent or completion of study protocol
Query!
Study design
Purpose of the study
Treatment
Query!
Allocation to intervention
Randomised controlled trial
Query!
Procedure for enrolling a subject and allocating the treatment (allocation concealment procedures)
allocation contained within sealed opaque envelopes
Query!
Methods used to generate the sequence in which subjects will be randomised (sequence generation)
Simple randomisation - recruitment target set and the same number of opaque sealed envelopes prepared, half containing one sequence allocation and half containing the alternate sequence allocation
Query!
Masking / blinding
Blinded (masking used)
Query!
Who is / are masked / blinded?
The people administering the treatment/s
The people assessing the outcomes
Query!
Query!
Query!
Query!
Intervention assignment
Crossover
Query!
Other design features
Query!
Phase
Phase 4
Query!
Type of endpoint/s
Efficacy
Query!
Statistical methods / analysis
There were no precedent studies on which to base sample size estimations for powering this study prior to commencement, as most pharmaceutical trials comparing efficacy had compared medications rather than devices and had seldom used outcomes other than lung function. During planning phase, published studies reporting statistically significant lung function outcomes for device comparisons, cited sample sizes of 10-21 subjects. Hence, subject recruitment target was set at 40; 20 subjects in each grouping.
To handle problems with missing data, we performed multiple imputation using the multivariate normal imputation (MVNI) approach. We assumed arbitrary missingness as the missing data mechanism showed a mixture of monotone and non-monotone missingness. Using imputations, we performed repeated measures ANOVA in order to estimate the effects of exposure to inhaler devices (Accuhaler versus MDI/s), inhaler techniques (adequate versus inadequate) and study inclusion group on the outcome variables. We used imputed datasets to perform repeated measures ANCOVA to estimate the effect of baseline lung function on the study’s outcome measures. T-tests were used to test the significance of each. The ANOVA and ANCOVA results were finally pooled using Rubin’s method. All models were adjusted for period effect, sequence effect and subject(sequence) effect. The effect size for exposure to inhaler devices or inhaler technique was estimated as the mean difference of the dependent variable between the category whose effect was assessed and the category whose effect was not.
Query!
Recruitment
Recruitment status
Stopped early
Query!
Data analysis
Data analysis is complete
Query!
Reason for early stopping/withdrawal
Lack of funding/staff/facilities
Participant recruitment difficulties
Query!
Date of first participant enrolment
Anticipated
Query!
Actual
15/11/2009
Query!
Date of last participant enrolment
Anticipated
Query!
Actual
11/03/2015
Query!
Date of last data collection
Anticipated
Query!
Actual
3/06/2015
Query!
Sample size
Target
40
Query!
Accrual to date
Query!
Final
28
Query!
Recruitment in Australia
Recruitment state(s)
NSW
Query!
Recruitment hospital [1]
9648
0
Campbelltown Hospital - Campbelltown
Query!
Recruitment hospital [2]
9649
0
Camden Hospital - Camden
Query!
Recruitment postcode(s) [1]
18412
0
2560 - Campbelltown
Query!
Recruitment postcode(s) [2]
18413
0
2570 - Camden
Query!
Funding & Sponsors
Funding source category [1]
298312
0
Charities/Societies/Foundations
Query!
Name [1]
298312
0
Royal Australasian College of Physicians
Query!
Address [1]
298312
0
145 Macquarie St, Sydney NSW 2000
Query!
Country [1]
298312
0
Australia
Query!
Funding source category [2]
298313
0
University
Query!
Name [2]
298313
0
Western Sydney University
Query!
Address [2]
298313
0
Narellen and Gilchrist Dr.,
Campbelltown
NSW 2560
Query!
Country [2]
298313
0
Australia
Query!
Primary sponsor type
Hospital
Query!
Name
Campbelltown Hospital
Query!
Address
Therry Rd.,
Campbelltown
NSW 2560
Query!
Country
Australia
Query!
Secondary sponsor category [1]
297425
0
University
Query!
Name [1]
297425
0
western Sydney University
Query!
Address [1]
297425
0
Narellen and Gilchrist Dr.,
Campbelltown
NSW 2560
Query!
Country [1]
297425
0
Australia
Query!
Ethics approval
Ethics application status
Approved
Query!
Ethics committee name [1]
299308
0
South Western Sydney Local Health District Human Reseach Ethics Committee
Query!
Ethics committee address [1]
299308
0
Locked Bag 7103 LIVERPOOL BC NSW 1871
Query!
Ethics committee country [1]
299308
0
Australia
Query!
Date submitted for ethics approval [1]
299308
0
15/03/2009
Query!
Approval date [1]
299308
0
15/10/2009
Query!
Ethics approval number [1]
299308
0
HREC/09/LPOOL/15
Query!
Summary
Brief summary
In COPD, inhaler capability may be impaired due to advanced age, comorbid illness and airway mechanics. Observational study - looks at COPD patient characteristics and how they relate to inhaler capability in acute COPD exacerbation and recovery phase. Interventional study - published pharmaceutical trials predominantly compare drug effects on lung function without accounting for differing inhaler devices or exploring outcomes reflecting chronic disease morbidity. This trial specifically compares two devices in terms of clinical outcomes.
Query!
Trial website
Query!
Trial related presentations / publications
BLS Chuong-Koon-Shin, B Cochrane, T Kemp, S Hutchings, SW Foo "Impact of education on inhaler technique in an inpatient population admitted with acute exacerbation of COPD (AECOPD)" poster presentation at APSR 2012 (Hong Kong)
Query!
Public notes
Query!
Contacts
Principal investigator
Name
79998
0
Dr Belinda Cochrane
Query!
Address
79998
0
Campbelltown Hospital
PO box 149
Campbelltown
NSW 2560
Query!
Country
79998
0
Australia
Query!
Phone
79998
0
+61 2 46344001
Query!
Fax
79998
0
+61 2 46344011
Query!
Email
79998
0
[email protected]
Query!
Contact person for public queries
Name
79999
0
Belinda Cochrane
Query!
Address
79999
0
Campbelltown Hospital
PO Box 149
Campbelltown
NSW 2560
Query!
Country
79999
0
Australia
Query!
Phone
79999
0
+61 2 46344001
Query!
Fax
79999
0
+61 2 46344011
Query!
Email
79999
0
[email protected]
Query!
Contact person for scientific queries
Name
80000
0
Belinda Cochrane
Query!
Address
80000
0
Campbelltown Hospital
PO Box 149
Campbelltown
NSW 2560
Query!
Country
80000
0
Australia
Query!
Phone
80000
0
+61 2 46344001
Query!
Fax
80000
0
+61 2 46344011
Query!
Email
80000
0
[email protected]
Query!
No information has been provided regarding IPD availability
What supporting documents are/will be available?
No Supporting Document Provided
Results publications and other study-related documents
Documents added manually
No documents have been uploaded by study researchers.
Documents added automatically
Source
Title
Year of Publication
DOI
Embase
Does device matter for inhaled therapies in advanced chronic obstructive pulmonary disease (COPD)? A comparative trial of two devices.
2019
https://dx.doi.org/10.1186/s13104-019-4123-5
N.B. These documents automatically identified may not have been verified by the study sponsor.
Download to PDF