Please note that the copy function is not enabled for this field.
If you wish to
modify
existing outcomes, please copy and paste the current outcome text into the Update field.
LOGIN
CREATE ACCOUNT
LOGIN
CREATE ACCOUNT
MY TRIALS
REGISTER TRIAL
FAQs
HINTS AND TIPS
DEFINITIONS
Trial Review
The ANZCTR website will be unavailable from 1pm until 3pm (AEDT) on Wednesday the 30th of October for website maintenance. Please be sure to log out of the system in order to avoid any loss of data.
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been endorsed by the ANZCTR. Before participating in a study, talk to your health care provider and refer to this
information for consumers
Download to PDF
Trial registered on ANZCTR
Registration number
ACTRN12619000875101
Ethics application status
Approved
Date submitted
3/06/2019
Date registered
19/06/2019
Date last updated
19/06/2019
Date data sharing statement initially provided
19/06/2019
Date results provided
19/06/2019
Type of registration
Retrospectively registered
Titles & IDs
Public title
Efficacy of Toric phakic intraocular lens implantation in eyes with astigmatism using image guided system.
Query!
Scientific title
Evaluation of axis alignment and Refractive results of Toric Phakic IOL using Image- Guided System in patients with moderate to high astigmatism.
Query!
Secondary ID [1]
298400
0
None
Query!
Universal Trial Number (UTN)
Query!
Trial acronym
Query!
Linked study record
Query!
Health condition
Health condition(s) or problem(s) studied:
Astigmatism
313097
0
Query!
Condition category
Condition code
Eye
311579
311579
0
0
Query!
Diseases / disorders of the eye
Query!
Intervention/exposure
Study type
Interventional
Query!
Description of intervention(s) / exposure
toric phakic posterior lens implantation to correct astigmatism
done by surgeons who have at least 20 years of experience. The approximate duration of surgery is 10 minutes for each eye. operation was done in the OR of an eye hospital.The current V4C ICL design was used. Under local anesthesia, dilating agents were administered. Preoperative digital reference imaging was obtained by Verion unit. In a temporal approach, after injection of viscoelastic material (Provisc, Alcon), a small 3.2 mm clear corneal incision was made and the ICL was injected through this incision into the anterior chamber and allowed to slowly unfold.After the injection and unfolding of the toric ICL into the anterior chamber, haptics were tucked under the iris. TICL was aligned to the desired axis by the guide of VERION digital marking.
Query!
Intervention code [1]
314644
0
Treatment: Devices
Query!
Comparator / control treatment
no control group
Query!
Control group
Uncontrolled
Query!
Outcomes
Primary outcome [1]
320285
0
toric ICL axis alignment evaluated by OPD machine
Query!
Assessment method [1]
320285
0
Query!
Timepoint [1]
320285
0
one week post operative
Query!
Secondary outcome [1]
371077
0
visual acuity with logMAR chart
Query!
Assessment method [1]
371077
0
Query!
Timepoint [1]
371077
0
one week postoperative
Query!
Secondary outcome [2]
371078
0
residual astigmatism with manifest refraction
Query!
Assessment method [2]
371078
0
Query!
Timepoint [2]
371078
0
one week postoperative
Query!
Eligibility
Key inclusion criteria
patients age 21 to 45 years old
astigmatism more than 1.5 D
free from other eye diseases
Query!
Minimum age
21
Years
Query!
Query!
Maximum age
45
Years
Query!
Query!
Sex
Both males and females
Query!
Can healthy volunteers participate?
No
Query!
Key exclusion criteria
patients younger than 21 according to manufacturer recommendation
patients with cataract or retina disease that can affect visual outcome
patients with AC depth less than 3 mm and WtW less than 10.6 mm or endothelial cell count less than 2000 cells / mm3
Query!
Study design
Purpose of the study
Treatment
Query!
Allocation to intervention
Non-randomised trial
Query!
Procedure for enrolling a subject and allocating the treatment (allocation concealment procedures)
Query!
Methods used to generate the sequence in which subjects will be randomised (sequence generation)
Query!
Masking / blinding
Query!
Who is / are masked / blinded?
Query!
Query!
Query!
Query!
Intervention assignment
Query!
Other design features
Query!
Phase
Not Applicable
Query!
Type of endpoint/s
Query!
Statistical methods / analysis
Query!
Recruitment
Recruitment status
Active, not recruiting
Query!
Date of first participant enrolment
Anticipated
Query!
Actual
18/09/2017
Query!
Date of last participant enrolment
Anticipated
Query!
Actual
1/05/2019
Query!
Date of last data collection
Anticipated
15/08/2019
Query!
Actual
Query!
Sample size
Target
30
Query!
Accrual to date
Query!
Final
24
Query!
Recruitment outside Australia
Country [1]
21555
0
United Arab Emirates
Query!
State/province [1]
21555
0
Dubai
Query!
Funding & Sponsors
Funding source category [1]
302941
0
Hospital
Query!
Name [1]
302941
0
Magrabi eye hospital
Query!
Address [1]
302941
0
Dubai health care city
Magrabi eye hospital
ALRAzi building #64 Block E 2nd floor
Dubai-UAE
Query!
Country [1]
302941
0
United Arab Emirates
Query!
Primary sponsor type
Hospital
Query!
Name
Magrabi eye hospital
Query!
Address
Dubai health care city
Magrabi eye hospital
ALRAzi building #64 Block E 2nd floor
Dubai-UAE
Query!
Country
United Arab Emirates
Query!
Secondary sponsor category [1]
302904
0
Individual
Query!
Name [1]
302904
0
Sherif Emerah
Query!
Address [1]
302904
0
Dubai health care city
Magrabi eye hospital
ALRAzi building #64 Block E 2nd floor
Dubai-UAE
Query!
Country [1]
302904
0
United Arab Emirates
Query!
Ethics approval
Ethics application status
Approved
Query!
Ethics committee name [1]
303503
0
Magrabi eye hospital ethics committee
Query!
Ethics committee address [1]
303503
0
Dubai health care city ALRazi building #64 Block E 2nd floor Magrabi eye hospital
Query!
Ethics committee country [1]
303503
0
United Arab Emirates
Query!
Date submitted for ethics approval [1]
303503
0
01/08/2017
Query!
Approval date [1]
303503
0
04/09/2017
Query!
Ethics approval number [1]
303503
0
Query!
Summary
Brief summary
Toric phakic IOLs are a largely reversible treatment option for patients who are not good candidates for laser refractive surgery and have significant astigmatism. Good alignment of toric IOL is crucial to achieve effective astigmatism correction. One degree of misalignment reduces the astigmatic correction by 3.3%. More than 30 degree of misalignment increasing the amount of preoperative astigmatism. Purpose of our study is to evaluate the accuracy of axis alignment , visual and refractive outcomes after toric phakic Visian toric implantable in patients with astigmatism more than 1.5D. METHODS: this retrospective study investigated toric ICL implantation in 24 eyes of 15 patients . Data were collected one week after toric ICL implantation.
Query!
Trial website
Query!
Trial related presentations / publications
Query!
Public notes
Query!
Contacts
Principal investigator
Name
93890
0
Dr Sherif Emerah
Query!
Address
93890
0
Dubai health care city
ALRazi building #64
Block E
2nd floor
Magrabi eye hospital
Query!
Country
93890
0
United Arab Emirates
Query!
Phone
93890
0
+971566538724
Query!
Fax
93890
0
Query!
Email
93890
0
[email protected]
Query!
Contact person for public queries
Name
93891
0
Sherif Emerah
Query!
Address
93891
0
Dubai health care city
ALRazi building #64
Block E
2nd floor
Magrabi eye hospital
Query!
Country
93891
0
United Arab Emirates
Query!
Phone
93891
0
+971566538724
Query!
Fax
93891
0
Query!
Email
93891
0
[email protected]
Query!
Contact person for scientific queries
Name
93892
0
Sherif Emerah
Query!
Address
93892
0
Dubai health care city
ALRazi building #64
Block E
2nd floor
Magrabi eye hospital
Query!
Country
93892
0
United Arab Emirates
Query!
Phone
93892
0
+971566538724
Query!
Fax
93892
0
Query!
Email
93892
0
[email protected]
Query!
Data sharing statement
Will individual participant data (IPD) for this trial be available (including data dictionaries)?
No
Query!
No/undecided IPD sharing reason/comment
Query!
What supporting documents are/will be available?
No Supporting Document Provided
Results publications and other study-related documents
Documents added manually
Type
Is Peer Reviewed?
DOI
Citations or Other Details
Attachment
Study results article
Yes
Emerah S. Evaluation of axis alignment and refract...
[
More Details
]
377708-(Uploaded-20-05-2020-11-06-09)-Journal results publication.pdf
Documents added automatically
Source
Title
Year of Publication
DOI
Dimensions AI
Evaluation of axis alignment and refractive results of toric phakic IOL using image-guided system
2020
https://doi.org/10.18240/ijo.2020.04.21
N.B. These documents automatically identified may not have been verified by the study sponsor.
Download to PDF