Please note that the copy function is not enabled for this field.
If you wish to
modify
existing outcomes, please copy and paste the current outcome text into the Update field.
LOGIN
CREATE ACCOUNT
LOGIN
CREATE ACCOUNT
MY TRIALS
REGISTER TRIAL
FAQs
HINTS AND TIPS
DEFINITIONS
Trial Review
The ANZCTR website will be unavailable from 1pm until 3pm (AEDT) on Wednesday the 30th of October for website maintenance. Please be sure to log out of the system in order to avoid any loss of data.
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been endorsed by the ANZCTR. Before participating in a study, talk to your health care provider and refer to this
information for consumers
Download to PDF
Trial registered on ANZCTR
Registration number
ACTRN12620000535976
Ethics application status
Approved
Date submitted
9/03/2020
Date registered
1/05/2020
Date last updated
1/05/2020
Date data sharing statement initially provided
1/05/2020
Type of registration
Prospectively registered
Titles & IDs
Public title
Atmo Gas capsule localisation study in healthy volunteers
Query!
Scientific title
Validation of Atmo Gas capsule localising technique via intestinal ultrasound in healthy volunteers
Query!
Secondary ID [1]
299849
0
AH-ALS02
Query!
Universal Trial Number (UTN)
U1111-1243-8772
Query!
Trial acronym
N/A
Query!
Linked study record
This record is a follow-up study for ACTRN12619001219178
Query!
Health condition
Health condition(s) or problem(s) studied:
Gastrointestinal dysmotility
316880
0
Query!
Condition category
Condition code
Oral and Gastrointestinal
313550
313550
0
0
Query!
Normal oral and gastrointestinal development and function
Query!
Intervention/exposure
Study type
Interventional
Query!
Description of intervention(s) / exposure
The study will involve ingestion of a wireless, gas-sensing (Atmo) capsule with simultaneous gastrointestinal ultrasound (GIUS) imaging to validate the localisation of the Atmo capsule. This study will occur once.
Following an overnight fast, the subjects will arrive at the Department of Gastroenterology, Alfred Hospital for the study. A baseline gastrointestinal ultrasound (GIUS) will be performed by an experienced GIUS-trained gastroenterologist to assess the participant's basic abdominal anatomy (the participant will be consenting and fully awake and be able to see the scan in real-time). The images from this scan are not recorded.
Following ingestion of the Atmo capsule, dynamic scanning using GIUS will commence following the transit of the capsule through the stomach and small intestine. Ultrasound images of the capsule passing through the pylorus (stomach) and ileocaecal junction will be taken. Images of these landmarks will record time and proof of capsule transit. Data will be collected in a coded manner. Ultrasound imaging will cease once arrival of the capsule in the large intestine has been confirmed.
Additionally, once the ultrasound imaging has been completed, participants will be allowed to leave the facility. Instructions on confirming passage of capsule during a bowel movement will be provided. It is anticipated that the Atmo capsule will take approximately 24-48 h to pass through the gastorintestinal system. Participants will also be instructed to keep the Atmo receiver close to their body (within 1.5 m) at all times.
Query!
Intervention code [1]
316106
0
Treatment: Devices
Query!
Comparator / control treatment
Gastrointestinal ultrasound (GIUS)
Gastrointestinal ultrasound is an attractive technique that is easily accessible and is not associated with radiation risk to participants. This method can recognise and distinguish anatomical structures according wall characteristics, size, contents and motility patterns. Thus, stomach, small bowel and colon have different appearances. The gas capsule is readily recognised sonographically. Visualisation of the gas capsule within the gastrointestinal tract has previously been performed in one healthy volunteer with good success. Additionally, with the improved image resolution of latest generation of GIUS machines and the clear visibility of the capsule sonographically. GIUS is able to accurately identify the ileo-caecal junction and, therefore, distinguish small and large intestine.
As outlined above, dynamic ultrasound scanning will be performed immediately from ingestion of Atmo capsule following the transit of the gas capsule throughout the gastrointestinal tract for the next 6 - 8 h. Continuous scanning will occur if gastric emptying or passage to the ileocaecal junction is anticipated.
Query!
Control group
Uncontrolled
Query!
Outcomes
Primary outcome [1]
323181
0
(a) confirmation of gastric emptying landmark using a composite of
(i) the time at which the first gradient inflection for the motility marker was recorded in the stomach (verified visually via graphs generated by the Atmo data receiver) AND
(ii) the times that direct visualisation of the capsule disappeared from the stomach/entered the duodenum on sonographic imaging.
Query!
Assessment method [1]
323181
0
Query!
Timepoint [1]
323181
0
Estimated within 4 h after ingestion of the Atmo capsule
Query!
Primary outcome [2]
323182
0
(b) confirmation of ileal-caecal junction using a composite of
(i) the time at which a second gradient inflection for the O2-equivalent motility marker was recorded after gastric emptying and no further temperature drop associated with water ingestion have occurred
AND
(b) the time via sonographic imaging that direct visualisation of the capsule entered the caecum.
Query!
Assessment method [2]
323182
0
Query!
Timepoint [2]
323182
0
Estimated within 6-8 h post-Atmo capsule ingestion
Query!
Secondary outcome [1]
381096
0
Gastric emptying time assessed by the Atmo capsule, defined as the duration between capsule ingestion and gastric emptying landmark and verified by sonographic images as the appearance of the capsule in the duodenum
Query!
Assessment method [1]
381096
0
Query!
Timepoint [1]
381096
0
Within 4 h post capsule ingestion
Query!
Secondary outcome [2]
381667
0
Whole gut transit time assessed by the Atmo capsule, defined as the duration between capsule ingestion and expulsion.
Query!
Assessment method [2]
381667
0
Query!
Timepoint [2]
381667
0
Within 24-48 h post-capsule ingestion
Query!
Secondary outcome [3]
381672
0
Small bowel transit times defined by duration between gastric emptying and proposed ileal-caecal junction as assessed using data from the Atmo capsule and verified by sonographic images.
Query!
Assessment method [3]
381672
0
Query!
Timepoint [3]
381672
0
Within 6-8 h
Query!
Secondary outcome [4]
381673
0
large bowel transit time defined as duration between ileal-caecal junction and passage of capsule as denoted by temperature drop or loss of signal coinciding with a bowel movement
Query!
Assessment method [4]
381673
0
Query!
Timepoint [4]
381673
0
Within 24-36 h
Query!
Eligibility
Key inclusion criteria
Healthy controls without known gastrointestinal disease/disorder
Query!
Minimum age
18
Years
Query!
Query!
Maximum age
55
Years
Query!
Query!
Sex
Both males and females
Query!
Can healthy volunteers participate?
Yes
Query!
Key exclusion criteria
history of gastrointestinal, endocrine or neurological disorders known to influence gastrointestinal motility, dysphagia, presence of suspected strictures, radiation enteritis or gastric bezoar; pregnancy; individuals with a body mass index >30 kg/m2, those with previous abdominal surgery (except appendicectomy) or implantable devices such as a pacemaker; antibiotic, prebiotic or probiotic use in the last 4 weeks; intake of proton pump inhibitors, H2 receptor antagonists, antacids in the last 7 days or prokinetics in the last 2 days; those who are currently receiving diathermy or have planned MRI or diathermy in the next 2 months.
Query!
Study design
Purpose of the study
Diagnosis
Query!
Allocation to intervention
Non-randomised trial
Query!
Procedure for enrolling a subject and allocating the treatment (allocation concealment procedures)
None
Query!
Methods used to generate the sequence in which subjects will be randomised (sequence generation)
None
Query!
Masking / blinding
Open (masking not used)
Query!
Who is / are masked / blinded?
Query!
Query!
Query!
Query!
Intervention assignment
Single group
Query!
Other design features
Query!
Phase
Not Applicable
Query!
Type of endpoint/s
Bio-equivalence
Query!
Statistical methods / analysis
Descriptive data will be used to report the outcomes of the study. Comparison will be made between (a) the times of exit from the stomach and the first O2-equivalent gradient inflection; and (b) the times of the passage of the capsule into the caecum and the occurrence of anaerobic conditions. Equivalence will be defined as an agreement of less than or equal to 25% between the two devices (or less than or equal to 30% as previously defined by Rao et al. 2009). A second approach to demonstrating equivalence will also be explored via linear regression and by assessing degrees of agreement between the paired time points using the Bland-Altman plots. Agreement is considered strong if 95% values lie within ±2 SD of mean differences. The results, conduct and reporting of the study will conform with the STARD 2015 guidelines (http://www.equator-network.org/reporting-guidelines/stard/).
Query!
Recruitment
Recruitment status
Not yet recruiting
Query!
Date of first participant enrolment
Anticipated
1/06/2020
Query!
Actual
Query!
Date of last participant enrolment
Anticipated
1/11/2020
Query!
Actual
Query!
Date of last data collection
Anticipated
1/12/2020
Query!
Actual
Query!
Sample size
Target
15
Query!
Accrual to date
Query!
Final
Query!
Recruitment in Australia
Recruitment state(s)
VIC
Query!
Recruitment hospital [1]
16099
0
The Alfred - Melbourne
Query!
Recruitment postcode(s) [1]
29613
0
3004 - Melbourne
Query!
Funding & Sponsors
Funding source category [1]
304306
0
Commercial sector/Industry
Query!
Name [1]
304306
0
Atmo Biosciences
Query!
Address [1]
304306
0
436 Elgar Rd
Box Hill VIC 3128
Query!
Country [1]
304306
0
Australia
Query!
Primary sponsor type
University
Query!
Name
Monash University
Query!
Address
Level 6 The Alfred Centre
99 Commercial Rd
Melbourne VIC 3004
Query!
Country
Australia
Query!
Secondary sponsor category [1]
304551
0
None
Query!
Name [1]
304551
0
Query!
Address [1]
304551
0
Query!
Country [1]
304551
0
Query!
Ethics approval
Ethics application status
Approved
Query!
Ethics committee name [1]
304759
0
Monash University Human Research Ethics Committee
Query!
Ethics committee address [1]
304759
0
Room 111, Chancellery Building D, 26 Sports Walk, Clayton Campus Research Office Monash University VIC 3800
Query!
Ethics committee country [1]
304759
0
Australia
Query!
Date submitted for ethics approval [1]
304759
0
11/11/2019
Query!
Approval date [1]
304759
0
11/12/2019
Query!
Ethics approval number [1]
304759
0
22438
Query!
Summary
Brief summary
The invention of an ingestible gas-sensing capsule promises a world of possibilities in research understanding of the activities of the gut bacteria in response to food. This technology, named the ATMO capsule, is capable of detecting changes in multiple gas concentrations (oxygen, carbon dioxide, hydrogen and methane) as a result of bacterial breakdown of food components (e.g. fibre) as it travels through different parts of the digestive tract. The completion of Phase 1 clinical studies in 23 healthy controls have proven its safety and functionality. Further studies are now needed to explore the utility of this technology in a clinical setting, such as in the assessment of regional transit times. If these studies are successful, this will mean the availability of a technology that is low cost, non-invasive and potentially usable as a point-of-care testing for individuals with gut conditions. A particularly attractive feature of the ATMO capsule is its ability to distinguish the small (aerobic region) vs large intestine (anaerobic region) via changes in oxygen concentrations. A step-wise decrease in oxygen levels have also been proposed as landmarks for distinguishing movement from the stomach to the small intestine. However, these anatomical landmarks remain theoretical and require further validation. A study utilising a similar ingestible capsule (the SmartPill capsule) is already underway to achieve this goal but preliminary results from this study require validation via an non-invasive imaging technique - gastrointestinal ultrasound. We have previously had good success in locating the ATMO capsule in one healthy volunteer but further data are needed to visualise the ATMO capsule within two key proposed anatomical positions (stomach to duodenum; ileum to caecum) in order to provide a way of validating gas profile landmarks. We hypothesised that changes in oxygen-equivalent and hydrogen concentrations as measured by the gas capsule provide identification of key anatomical landmarks within the gastrointestinal tract. The aim of the study was to develop and validate markers of anatomical landmarks of the ATMO gas capsule using gastrointestinal ultrasound in healthy controls.
Query!
Trial website
None
Query!
Trial related presentations / publications
Query!
Public notes
Query!
Contacts
Principal investigator
Name
98114
0
Prof Peter Gibson
Query!
Address
98114
0
Level 6 The Alfred Centre
99 Commercial Rd
Melbourne VIC 3004
Query!
Country
98114
0
Australia
Query!
Phone
98114
0
+61399030640
Query!
Fax
98114
0
Query!
Email
98114
0
[email protected]
Query!
Contact person for public queries
Name
98115
0
CK Yao
Query!
Address
98115
0
Level 6 The Alfred Centre
99 Commercial Rd
Melbourne VIC 3004
Query!
Country
98115
0
Australia
Query!
Phone
98115
0
+61399030266
Query!
Fax
98115
0
Query!
Email
98115
0
[email protected]
Query!
Contact person for scientific queries
Name
98116
0
CK Yao
Query!
Address
98116
0
Level 6 The Alfred Centre
99 Commercial Rd
Melbourne VIC 3004
Query!
Country
98116
0
Australia
Query!
Phone
98116
0
+61399030266
Query!
Fax
98116
0
Query!
Email
98116
0
[email protected]
Query!
Data sharing statement
Will individual participant data (IPD) for this trial be available (including data dictionaries)?
No
Query!
No/undecided IPD sharing reason/comment
As this is a industry-funded project, data will by only be available via manuscript for publication in an international peer reviewed journal.
Query!
What supporting documents are/will be available?
No Supporting Document Provided
Doc. No.
Type
Citation
Link
Email
Other Details
Attachment
7296
Ethical approval
378764-(Uploaded-09-03-2020-20-52-54)-Study-related document.pdf
Results publications and other study-related documents
Documents added manually
No documents have been uploaded by study researchers.
Documents added automatically
No additional documents have been identified.
Download to PDF