Please note that the copy function is not enabled for this field.
If you wish to
modify
existing outcomes, please copy and paste the current outcome text into the Update field.
LOGIN
CREATE ACCOUNT
LOGIN
CREATE ACCOUNT
MY TRIALS
REGISTER TRIAL
FAQs
HINTS AND TIPS
DEFINITIONS
Trial Review
The ANZCTR website will be unavailable from 1pm until 3pm (AEDT) on Wednesday the 30th of October for website maintenance. Please be sure to log out of the system in order to avoid any loss of data.
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been endorsed by the ANZCTR. Before participating in a study, talk to your health care provider and refer to this
information for consumers
Download to PDF
Trial registered on ANZCTR
Registration number
ACTRN12608000240347
Ethics application status
Not yet submitted
Date submitted
7/05/2008
Date registered
8/05/2008
Date last updated
8/05/2008
Type of registration
Prospectively registered
Titles & IDs
Public title
A comparative trial of a new disposable laryngeal mask airway (LMA® SupremeTM) during anaesthesia in spontaneously breathing adult patients
Query!
Scientific title
A randomised, single-blinded, controlled trial of the LMA® SupremeTM disposable laryngeal mask versus LMA® ClassicTM during anaesthesia in spontaneously breathing adult patients
Query!
Universal Trial Number (UTN)
Query!
Trial acronym
Query!
Linked study record
Query!
Health condition
Health condition(s) or problem(s) studied:
Supralaryngeal device in spontaneuosly breathing patients
3120
0
Query!
Condition category
Condition code
Anaesthesiology
3283
3283
0
0
Query!
Anaesthetics
Query!
Intervention/exposure
Study type
Interventional
Query!
Description of intervention(s) / exposure
The intervention groups will receive either the LMA® SupremeTM (LMAS) or LMA® ClassicTM (LMAC) L aryngeal Mask Airway (LMA) for airway maintenance. We hypothesise that the LMA Supreme will provide superior cuff seal pressure than the classic LMA. We also believe the success rate on first attempt will be higher with the LMA Supreme. The ease of insertion, time to achieve effective airway, success rate on subsequent attempts, and incidence of oro-pharyngeal trauma will be measured and we believe they will be similar in all groups. The LMAC is a reusable supraglottic airway device that has been available since 1998 and is widely used during elective general anaesthesia where endotracheal intubation is not thought necessary. Newer single-use disposable supraglottic airway devices are now available, which potentially reduce the risk of infection transfer. The laryngeal mask is the most commonly used supraglottic device; its silicone construction ensures that it is easy to insert and minimises airway trauma. The Therapeutics Goods Administration in Australia has recently assessed a number of newer disposable LMAs, and they are now available for use in Australia. The LMAC is easy to insert, creates an effective airway seal but provides only limited protection against aspiration. The LMAC is silicone construction. The single use LMA Supreme is a new supraglottic airway device, which is a hybrid of the LMA Prosealâ„¢ (modified cuff for high seal pressures, integrated bite block and gastric access channel) and the LMA Fastrachâ„¢ (fixed curvature airway tube and guiding handle). These features should in theory enhance insertion,fixation, ventilation, airway protection and airway protection.Anaesthetic technique Routine anaesthetic monitoring, as per Australian and New Zealand College of Anaesthetists guidelines for general anaesthesia, will be instituted. A standardised general anaesthetic technique will be employed. Patients will not be pre-medicated. Induction of anaesthesia will utilise propofol 1-2 mg/kg, fentanyl (1-3 mg/kg), and midazolam (0.025-0.05 mg/kg), at the discretion of the anaesthetist concerned, to produce a loss of lash reflex. Following induction of anaesthesia patients undergo controlled ventilation using an anaesthetic facemask and 100% oxygen with sevoflurane (end tidal concentration at discretion of the anaesthetist). Following insertion of supraglottic airway device and return of spontaneous ventilation, maintenance of anaesthesia is to be achieved using sevoflurane (end tidal concentration at discretion of the anaesthetist) and a fresh gas flow with an inspired oxygen concentration of 70-100%. No nitrous oxide will be used. Small doses of metaraminol or phenylephrine can be administered to control systemic arterial blood pressure. Maintenance of general anaesthesia will be with sevoflurane in an oxygen:air mixture to achieve an inspired oxygen level of 70-100%. Insertion of supraglottic airway device A practitioner experienced in the use of LMA devices will carry out insertion. Routine recommended preinsertion tests of the control and study device will be performed. The airway device will be inserted when loss of lash reflex and jaw tone allows. Successful device placement will be confirmed by: · resistance to further downward movement of the device · cuff inflation with the appropriate volume of gas to achieve an intracuff pressure of 60cmH20. · effective ventilation as defined by assisted ventilation with chest wall movement, observance of a square wave capnograph trace and assisted ventilation without a leak at airway pressure of at least 10cmH20. At the conclusion of surgery the anaesthetic gases will be replaced by 100% oxygen to allow patient recovery. When protective reflexes are noted to have returned to normal, the airway device will be removed after deflation of the cuff. The device will be inspected for secretions and blood.
Query!
Intervention code [1]
2866
0
Treatment: Devices
Query!
Comparator / control treatment
LMA® SupremeTM disposable laryngeal mask (comparator) versus LMA® ClassicTM (control)
Query!
Control group
Active
Query!
Outcomes
Primary outcome [1]
4171
0
Airway pressure leading to cuff leakage immediately after induction of general anesthesia and placement of LMA, measured in cmH20. The LMAC sealing pressures are between 20-25cmH20. No study to date has directly compared the sealing pressures between the LMAC and other silicone based LMAs. This may have important consequences with the use of these devices in patients where it is considered difficult to maintain a patient airway during general anaesthesia. A standardised amount of air will be injected to achieve cuff inflation pressure of 60cmH20. A manometric stability test (to a maximum pressure of 40 cm H20) will be performed to determine LMA leak pressure.
Query!
Assessment method [1]
4171
0
Query!
Timepoint [1]
4171
0
Immediately after induction of anaesthesia
Query!
Secondary outcome [1]
7034
0
Failure to establish an adequate airway (maximum of three attempts, intra-op)
Query!
Assessment method [1]
7034
0
Query!
Timepoint [1]
7034
0
Immediate
Query!
Secondary outcome [2]
7035
0
First attempt insertion (intra-operative).
Query!
Assessment method [2]
7035
0
Query!
Timepoint [2]
7035
0
Based on observation intraoperatively.
Query!
Secondary outcome [3]
7036
0
Ease of insertion (intra-operative).
Query!
Assessment method [3]
7036
0
Query!
Timepoint [3]
7036
0
Assessed and reported by the Clinician at the end of the intervention period.
Query!
Secondary outcome [4]
7037
0
Time to achieve effective airway
Query!
Assessment method [4]
7037
0
Query!
Timepoint [4]
7037
0
intra-operative from induction of anaesthesia to time to achieve effective ventilation
Query!
Secondary outcome [5]
7038
0
Intra-cuff volume at standardized pressure or maximum intracuff pressure (intra-operative).
Query!
Assessment method [5]
7038
0
Query!
Timepoint [5]
7038
0
Measured at time of inflation of laryngeal mask.
Query!
Secondary outcome [6]
7039
0
Post-anaesthesia sore throat, hoarse voice and dysphagia in recovery (PACU).
Query!
Assessment method [6]
7039
0
Query!
Timepoint [6]
7039
0
Measured in recovery when the patient is awake and orientated and at 24 hours through question over telephone at 24 hours post-operatively.
Query!
Eligibility
Key inclusion criteria
Adult undergoing spontaneous ventilation general anaesthesia in whom a supraglottic airway device would have been chosen for maintenance of airway patency by the Anaesthetist responsible for the individual patient.
Query!
Minimum age
18
Years
Query!
Query!
Maximum age
No limit
Query!
Query!
Sex
Both males and females
Query!
Can healthy volunteers participate?
No
Query!
Key exclusion criteria
Individuals undergoing general anaesthesia in whom it would not have been appropriate to insert a supraglottic airway device for airway patency as determined by the anaesthetist responsible for that patient will be excluded. Such patients include:· Patients with morbid obesity (Body Mass Index 35 kg/m2)· Risk of aspiration· Limited interincisor distance (2.5 cm)· Known difficult airway.Patients who are unable to communicate in English, because of a language barrier, cognitive deficit or intellectual disability will not be approached.
Query!
Study design
Purpose of the study
Treatment
Query!
Allocation to intervention
Randomised controlled trial
Query!
Procedure for enrolling a subject and allocating the treatment (allocation concealment procedures)
Randomisation results will be concealed in opaque envelopes until after patient consent has been obtained.
Query!
Methods used to generate the sequence in which subjects will be randomised (sequence generation)
Computer generated random sequence.
Query!
Masking / blinding
Blinded (masking used)
Query!
Who is / are masked / blinded?
Query!
Query!
Query!
Query!
Intervention assignment
Parallel
Query!
Other design features
Blinding: subjects, data analyst. Un-blinded: Anaesthetist and assessor.
Query!
Phase
Phase 4
Query!
Type of endpoint/s
Efficacy
Query!
Statistical methods / analysis
Query!
Recruitment
Recruitment status
Not yet recruiting
Query!
Date of first participant enrolment
Anticipated
14/07/2008
Query!
Actual
Query!
Date of last participant enrolment
Anticipated
Query!
Actual
Query!
Date of last data collection
Anticipated
Query!
Actual
Query!
Sample size
Target
100
Query!
Accrual to date
Query!
Final
Query!
Recruitment in Australia
Recruitment state(s)
Query!
Funding & Sponsors
Funding source category [1]
3363
0
Hospital
Query!
Name [1]
3363
0
Royal Melbourne Hospital
Query!
Address [1]
3363
0
Grattan Street
Parkville
Victoria 3050
Query!
Country [1]
3363
0
Australia
Query!
Primary sponsor type
Individual
Query!
Name
Investigator Initiated (Daryl Williams)
Query!
Address
Grattan Street
Parkville
Victoria 3050
Query!
Country
Australia
Query!
Secondary sponsor category [1]
3010
0
None
Query!
Name [1]
3010
0
Query!
Address [1]
3010
0
Query!
Country [1]
3010
0
Query!
Ethics approval
Ethics application status
Not yet submitted
Query!
Ethics committee name [1]
5388
0
Query!
Ethics committee address [1]
5388
0
Query!
Ethics committee country [1]
5388
0
Query!
Date submitted for ethics approval [1]
5388
0
19/03/2008
Query!
Approval date [1]
5388
0
Query!
Ethics approval number [1]
5388
0
2008.035
Query!
Ethics committee name [2]
5389
0
Melbourne Health HREC
Query!
Ethics committee address [2]
5389
0
Grattan Street Parkville Victoria 3050
Query!
Ethics committee country [2]
5389
0
Australia
Query!
Date submitted for ethics approval [2]
5389
0
19/03/2008
Query!
Approval date [2]
5389
0
Query!
Ethics approval number [2]
5389
0
2008.035
Query!
Summary
Brief summary
Patients presenting for surgery at RMH eligible for LMA general anaesthesia
Query!
Trial website
no
Query!
Trial related presentations / publications
no
Query!
Public notes
Query!
Contacts
Principal investigator
Name
28573
0
Query!
Address
28573
0
Query!
Country
28573
0
Query!
Phone
28573
0
Query!
Fax
28573
0
Query!
Email
28573
0
Query!
Contact person for public queries
Name
11730
0
Daryl Williams
Query!
Address
11730
0
Grattan Street
Parkville
Victoria 3050
Query!
Country
11730
0
Australia
Query!
Phone
11730
0
613 9342 7540
Query!
Fax
11730
0
Query!
Email
11730
0
[email protected]
Query!
Contact person for scientific queries
Name
2658
0
Daryl Williams
Query!
Address
2658
0
Grattan Street
Parkville
Victoria 3050
Query!
Country
2658
0
Australia
Query!
Phone
2658
0
613 9342 7540
Query!
Fax
2658
0
Query!
Email
2658
0
[email protected]
Query!
No information has been provided regarding IPD availability
What supporting documents are/will be available?
No Supporting Document Provided
Results publications and other study-related documents
Documents added manually
No documents have been uploaded by study researchers.
Documents added automatically
No additional documents have been identified.
Download to PDF